100Dh Live Time Factor

Function

This object is a multiplier that is multiplied by object 100Ch to yield the time window for the "node guarding" protocol in milliseconds.

This object is only present in device variants with a CANopen connection.

Object description


Index 100Dh
Object Name Live Time Factor
Object Code VARIABLE
Data type UNSIGNED8
Saveable yes, category: communication
Access Read/write
PDO Mapping No
Admissible Values  
Specified Value 00h
Firmware Version FIR-v1426